TM  55-1520-240-23-8 10-10 FUEL  CELL DAMAGE  —  CLASSIFICATION  AND  REPAIR  LIMITS  (GENERAL INFORMATION) (Continued) 10-10 h. Deleted. i. Repair/Replacement  of  Internal and  External Support  Fittings  (Task  10-12  or  10-15.1). Task  10-12  (exterior)  or  10-15.1  (interior) shall  be  used  with  the  following  changes: (1) Omit  step  1d  as  the  support  fitting  is the patch. (2) Omit  steps  1h/1m,  1i/1n,  and  1j/1o  from Tasks  10-12  and  10-15.1  respectively, and  incorporate:  Apply one  uniform  brush coat  of  repair  cement  (E63.2)  to  the prepared  bonding  surface  of  the  support fitting  and  to  the  cell  wall.   Carefully position  the  support fitting  in  the  proper location  and  press  down  firmly  with finger  pressure  to  force  out  any  trapped air.   Make  sure  fitting  does  not  move  off location  during  cure. NON-REPARABLE  DAMAGE 4. Damage  that  is  not  reparable  is  classified  as follows: a. Damage  which  extends  into  a  corner  or  step off  area  that  involves  a  cut  longer  than  4 inches  is  not  reparable. b. Damage  which  has  led  to  activation  of the sealant  ply/plies  is not  reparable. c. Damage  to  cells  which  cannot be  repaired by  cement  or  reinforced  patching  is  not reparable. FOLLOW  ON  MAINTENANCE: None END  OF  TASK 10-50