TM  55-1520-240-23-8 10-5 INSPECT FUEL TANKS  — HARD  LANDING (Continued) 10-5 f. Check  two  lanyard-release  electrical connectors (14).  Connectors  shall  be  secure. INSPECT FORWARD  FUEL TANK NOTE Procedure  is  same  to  inspect  either forward  fuel  tank  after suspected  hard landing.  Left  side  is  shown  here. 2. Check  forward  fuel  tank  (15) as follows: a. Check  access  door (16) on  aft  end  of  tank (15).  Door  shall  be  secure  and  there  shall  be no  missing  bolts  (17). b. Check  fittings (18, 19,  and  20) on  aft  end  of tank  (15).   Fittings shall  be  secure. c. Check  access  door (21) on  forward  end  of tank.  Door shall be  secure  and  there  shall  be no  missing  bolts  (22). d. Check  areas around  tank  unit (23)  and  tank filler adapter (24).  There  shall be  no  missing rivets. e. Check  lanyard-release  electrical  connector (25).   Connector shall  be  secure. 10-36