TM  55-1520-240-23-8 10-4 INSPECT  FUEL TANK ASSEMBLIES (Continued) 10-4 INSPECT  AFT  FUEL  TANK 14. Check  interior  of  aft  pod  (8).   There  shall  be no  damage,  layer  separation,  leakage,  or contamination. 15. Check  cell  (9).  There  shall  be  no  damage,  layer separation, no  fuel  in  self-sealing  layers,  and  no green,  sponge-like  material. 16. Check  interior of cell  (9).   Interior  shall  not  be contaminated  with  mold. 17. Check  exterior surface  of  cell  (9).   Anti-chafing tape  shall  be  secure,  and  there  shall  be  no chafing  damage. 18. Check  hoses,  fittings,  and  tubing  inside  cell  (9). There  shall  be  no  damage  or deterioration. 19. Check  vent drain  lines  (10).  Lines must not  have high  or low  spots  that  can  trap  fluid. 20. Check  support  structure  (11).  Support structure shall  not  be  damaged. 21. Check  hinges  (12)  and  hinge  pins  (13).  Hinges and  pins  shall  not be  worn  or damaged. FOLLOW-ON MAINTENANCE: Perform  vent  system  pressure  test  (Task 10-117). Install aft tank access  doors  (Task  10-80). Install forward  tank access doors  (Task 10-70). Install  main  tank  access  doors  (Tasks  10-52  and 10-54). Raise  and  install  aft fuel  tanks (Task 10-31). Raise  and  install forward  fuel tanks (Task  10-26). Raise  and  install  main  fuel  tanks (Task  10-21). Install main  fuel tank vent fairings  (Task 10-64). Perform  vent  system  flow test  (Task 10-118). Perform  test  of  pressure  refueling  system  (Task 10-119) and  fuel  feed  system  (Task  10-120). Install aft intertank  pod  panels  (Task 2-188). Close  forward  landing  gear  access  panels  (Task 2-179  and  2-181). Service  fuel  tanks  (Task  1-51). Bleed  fuel  system  (Task 10-121). END  OF  TASK 10-33