TM  55-1520-240-23-8 10-3 PURGING OF  FUEL TANK WITH AIR (Continued) 10-3 If  heater  and  plenum  chamber  are used  with  blower,  start  heater before connecting  heater  duct  to  plenum chamber. Do  not shut  off air flow while  air duct is  attached  to  helicopter. If power fails,  remove  duct and  blower from  area  until  normal  air  flow  is restored. 11. Open  pod  access  panel  (10) for the  tank  being purged  (Task  2-2). 12. Position  and  ground  air blower (11). 13. Start  blower  (11) and  air mover  (2). 14. Connect  duct (12) to  blower. 15. Connect  duct ground  receptacle  (13)  to  aircraft plug  (14). 16. Position  duct (12) to  blow air  at  45º  angle  across tank  access door (15). 17. Remove  tank  access  door  (15),  forward  tank (Task 10-69),  main  tank  (Task 10-51  or 10-53), and  aft  tank  (Task  10-79). 18. Position  duct  (12)  to  blow  into  fuel  tank  (16) through  access  hole  (15).   Maintain  use  of  air mover if  working  inside  fuel  cell. 19. After  15 minutes  remove  air  duct  (12) from  fuel tank  down  and  remove  air  blower (10). 20. Test  purged  tank.   Use  a  combustible  gas indicator.   If  level  of  fumes  is  still  dangerous, purge  until  level  is  safe. 21. Close  supply  valve  (3).   Remove  air  mover (2). Disconnect ground  receptacle  (6). 10-29