TM  55-1520-240-23-8 10-2 PURGING  OF FUEL TANK  WITH  INERT  GAS (Continued) 10-2 2. Remove  horn  from  nozzle  (3)  of CO2  bottle  (4). 3. Remove  fuel  tank  filler  cap  (5). 4. Install  grounding  receptacle  (6)  from  nozzle  (3) and  bottle  (4)  into  helicopter  plug  (7). 5. Insert  nozzle  (3)  into  open  filler  hole  (8)  in  fuel tank  (9).   Discharge  bottle  at  a  flow  rate  of  1 pound-per-minute. NOTE Use  two  15  pound  CO2  bottles  to purge  a  main  fuel  tank.  Use  one  15 pound bottle  for  a  forward  or  aft tank. 6. Test  purged  tank  (9).   Use  a  combustible  gas indicator  or  equivalent tester.  If level  of  fumes  is not  safe,  purge  until  level  is  safe. 7. Remove  grounding  receptacle  (6)  from  helicopter plug  (7).  Remove  bottle  (4). 8. If personnel  will  work within  the  tank, purge  with air  (Task  10-3). 9. Install  tank filler  cap  (5). FOLLOW-ON  MAINTENANCE: None END  OF  TASK 10-26