TM  55-1520-240-23-8 10-2 PURGING OF FUEL TANK  WITH  INERT GAS (Continued) 10-2 When  using  a  fire  extinguisher as a  source  of  CO2  for  purging  fuel tanks,  remove  fiber  horn.   Ground nozzle  as  well  as  bottle  itself  to aircraft.   Discharge  CO2  slowly  to avoid  generating  static  electricity and allowing  rapid  CO2  expansion  which could  damage  the  cell. NOTE The  size  of  CO2  bottle  used  can vary to  meet  existing  conditions,  with 15  pound size  handy  to  use.   Total amounts recommended  are  based on  quantities  usually  needed,  but more  may  be  needed  to  obtain  a  safe reading  on  combustible  gas indicator. Nitrogen  or  other  inert  gas  may be  used  instead  of  CO2.   Carefully observe  above  precautions. Procedure  is  same  to  purge  any  fuel tank.   No.   1  (left)  main  fuel  tank purging  is shown  here. 1. Make  sure  that  tank  vent  (1)  is  clear  of obstructions  and  plugs,  and  that  tank  drain valves (2)  are  installed  and  closed. While  purging,  each  person  shall wear  protective  clothing,  a  respirator, a  full  facepiece  and  rubber  gloves. Perform  the  purging  operation  in  an area  isolated  from  personnel  not concerned  with  purging. 10-25