TM  55-1520-240-23-8 10-1 FUEL  SYSTEM (Continued) 10-1 Drain  Valves  — There  are  two  drain  valves  in  each  tank,  one  aft  and one  forward.  The  forward  valve  is  a  sump  drain.  The  aft valve  is  a  sump  drain  and  is  open  to  the  vent  system. Vent  System  — The  vent  system  in  each  tank  is  made  up  of  tubes  and two  vent  boxes.   The  system  allows  outside  air  to  enter and  exit  the  fuel  cell  during  refueling  and  fuel  usage. The  system  also  prevents  fuel from  spilling  in  the  event of  a  rollover. Fuel  Quantity Probes  — Each  fuel  subsystem  has  a  fuel  quantity  indicating system.   Five  tank  quantity  transmitter  probes  (one  in each  auxiliary  tank  and  three  in  the  main  tank)  provide input  to  the  indicating  system .  The  fuel  quantity  signal is  directed  through  a  seven  position  switch  to  a  fuel quantity  indicator  on  the  center  instrument  panel.   The selector  enables  the  operator  to  read  fuel  quantity  in each  of  the  six  tanks  individually,  or  to  read  the  total fuel quantity.  Probe  support  cups,  located  on  the  bottom  of the  cell,  prevent  excessive  movement  of  the  fuel  probes. 10-4