TM  55-1520-240-23-7 8-19 TEST DUAL TORQUEMETER INDICATOR  (AVIM) 8-19 INITIAL  SETUP Applicable Configurations: Without 74 Tools: Electrical  Repairer’s  Tool Kit,  NSN  5180-00-323-4915 AC  Power  Supply,  115  Volt  400  Hz Meter  Test  Set,  TS-682A/GSM-1 Soldering  Gun Crimping  Tool,  NSN  5120-00-075-2544 Connector,  PT06CE8-4S Connector,  M53476W12-10S Wire,  No.   20,  Insulated Personnel  Required: Aircraft  Electrician Inspector References: TM  11-6625-277-14 Equipment  Condition: Off  Helicopter  Task Electrical  Test  Setup NOTE Connect  1 MA  or 10 vdc  test  leads to  indicated  jack  only  when  specified in  test  procedure. Intermixing  of  P/N  114ES270-3  and 114ES70-4  on  the  same  aircraft  is not  allowed. 1. Connect  indicator  (1)  to  test  setup. 2. Connect  10 vdc  lead  (2)  and  COMMON  lead  (3) to  meter  test  set  (4)  jacks. 3. Apply  power  to  power  supply  (5). 8-61