TM  55-1520-240-23-7 8-11 TEST GAS  PRODUCER TACHOMETER  GENERATOR (Continued) 8-11 1. Attach  generator  (1)  to  test  set  (2)  (TM 11-6625-673-15-1). 2. Turn  on  power  supply  (3). 3. Turn  on  and  adjust test  set (2).  Check  generator (1)  at the  following  settings  by operating  test  set switch  (4) from TEST  GEN to  MASTER GEN and comparing  indications (TM  11-6625-673-15-1). DRIVE  SPEED  RPM  X1 INDICATOR INDICATION  PERCENT TEST SET  INDICATOR INDICATION  TOLERANCE 0 0 ±0.5 1050 25 ±0.6 2100 50 ±0.8 3150 75 ±0.5 4200 100 ±0.5 4600 110 ±0.5 4. Repeat step  2  in  reverse  order. 8-35