TM  55-1520-240-23-7 8-2 TEST  POWER TURBINE INLET TEMPERATURE  (PTIT)  INDICATOR 8-2 INITIAL  SETUP Applicable  Configurations: All Tools: Electrical  Repairer’s Tool  Kit, NSN 5180-00-323-4915 Tester, Exhaust Gas Temperature Model BH112JB-53 Power  Supply,  28  VDC Multimeter Connector,  M83723-75W1407N Light  Indicator,  MS25041-4 Lamp,  MS25237-327 Wire,  No.   20  Insulated Materials: Solder (E360) Personnel  Required: Aircraft  Electrician Inspector References: TM  55-1500-323-25 TM  55-4920-401-13&P Equipment  Condition: Off  Helicopter  Task Test  Setup 1. Connect  indicator (1) to  test  setup. 2. Apply  28  vdc  to  test setup. FRICTION  TEST 3. Slowly adjust  tester (2) to  cause  indicator (1) to read  200ºC.  Record  indicator reading. 4. Tap  indicator  (1).  Record  indicator reading. 5. Compare  indicator (2) readings  from  steps  3  and 4.  Difference  shall  be  no  more  than  24ºC. 6. Repeat steps 3, 4, and  5 at 400ºC, 700ºC, 800ºC, 900ºC, and 1200ºC. Difference  shall  be  no  more than  24ºC at  all  noted  settings. 8-16