TM  55-1520-240-23-6 7-11 PREPARE  FLIGHT CONTROL  HYDRAULIC SYSTEM  AFTER  FLUSHING (PRESSURE LINES) 7-11 INITIAL  SETUP Tools: Hydraulic Repairer’s Tool Kit, NSN 5180-00-323-4891 Container Hydraulic  Test  Stand Filter Assembly Kit  ADHT  6814-M9716M Workstand Materials: Cloths  (E120) Gloves  (E186) Parts: Hoses Unions Fittings Personnel  Required: Aircraft  Pneudraulic  Repairer Inspector Equipment  Condition: Flushing  Flight  Control Hydraulic  System  (Pressure Lines)  Completed  (Task 7-10) General Safety Instructions: Hydraulic fluid  (E199)  is toxic.   It  can irritate  skin  and  cause  burns.   Avoid inhaling.   Use  only  with  adequate ventilation.  Avoid  contact  with  skin, eyes,  or  clothing.  In  case  of contact, immediately  flush  skin  or eyes  with water  for  at  least 15 minutes.   Get medical  attention  for eyes. Hydraulic fluid  ejected  under pressure can  cause  injury  to  personnel. Hydraulic fluid  sprayed  into  the  air  is a  fire  hazard. 7-68