TM  55-1520-240-23-6 7-10 FLUSHING FLIGHT CONTROL HYDRAULIC SYSTEM  (PRESSURE LINES) (Continued) 7-10 NOTE Test  stand  filters  must  be  cleaned before  connecting  test  stand  to helicopter. Make  sure  filter  assembly  kit ADHT6814-M9716M  is  installed  in test  stand  pressure  line. To  operate  hydraulic  test  stand, refer to  applicable  manual. 1. Open  shutoff  valve  in  test stand  return  line. Keep  test  stand  bypass valve  closed. Otherwise,  contaminants  could reenter the  system. 2. Set  test  stand  to  deliver 10 gpm  at  500  psi pressure. 3. Start  test stand  and  slowly fill lines  with  hydraulic fluid.  Check  system  for leaks. 4. Flush  system for 5 minutes to  make  sure  system is  filled. 5. Shut  down  test stand. 6. At  No.  2  lower controls module  location, remove bypass hose  (1) from  pressure  line  (2).  Plug  and cap  both  lines.  Wear gloves (E184.1). 7-65