TM  55-1520-240-23-6 7-9 PREPARE  FLIGHT CONTROL HYDRAULIC  SYSTEM  FOR  FLUSHING  (PRESSURE LINES) (Continued) 7-9 Hydraulic fluid  (E199)  is toxic.   It  can irritate  skin  and  cause  burns.   Avoid inhaling.   Use  only  with  adequate ventilation.  Avoid  contact  with  skin, eyes,  or clothing.  In  case  of contact, immediately flush  skin  or eyes  with water  for  at  least 15 minutes.   Get medical  attention  for eyes. Hydraulic fluid  ejected  under pressure can  cause  injury  to  personnel. Hydraulic fluid  sprayed  into  the  air is a  fire  hazard. NOTE Test  stand  filters  must  be  cleaned before  connecting  test  stand  to helicopter. Make  sure  filter  assembly  kit ADHT6814-M9716M  is  installed  in test  stand  pressure  line. NO  BREAK  -  WORK  HARDER NO  BREAK  -  WORK  HARDER NO.  2  PUMP 1. Disconnect pressure  line  (1)  from  No.   2  flight control  pump  (2).   Cap  open  port  (3)  on  pump. Use  gloves  (E186). 2. Attach  pressure  line  (4)  from  test  stand  to pressure  line  (1).   Use  union  (5). 7-59