TM  55-1520-240-23-6 7-8 INSPECT FOR CONTAMINATION OF HYDRAULIC SYSTEMS (Continued) 7-8 1. Check  all  six  hydraulic  filters  (1).   Inspect that red  indicator button  (2) on  bottom  of  each  filter has  not  extended. 2. If button  (2) is  extended, apply hydraulic power to that  system. 3. Depress  button  (2).   If  checking  utility  system, have  pilot  in  cockpit  motor either engine  for  30 seconds.  If  checking  flight  control  system, have pilot in  cockpit cycle  control stick for 30 seconds. If  button  extends,  filter element is  clogged. 4. Remove  hydraulic  power. 5. Remove  filter element on  all  contaminated  filters (Tasks  7-33,  7-156, and  7-194  as required). 6. Inspect removed  element  and  determine  source of  contamination  (FM  1-509). 7. Install  new  filter  element (Task  7-34,  7-157,  or 7-195  as  required). FOLLOW-ON MAINTENANCE: As  required. Close  right  forward  walk  platform  (Task 2-2). Close  pylon  right access  door (Task  2-2). END  OF  TASK 7-55