TM  55-1520-240-23-6 7-6 REPLACE  ROSAN ADAPTERS  AND  REDUCERS (Continued) 7-6 9. Remove  Rosan  fitting  (6) from port (8) as  follows: a. Select proper  wrench  (10) from  table  1. b. Engage  wrench  serrations  with  those  of adapter  (9). c. Turn  wrench  (10)  counterclockwise  to unscrew  fitting  (6) from  port  (8). 10. Remove  fitting  (6) from  port  (8). NOTE Rosan  fittings  cannot  be  repaired and  must  be  replaced  if threads  are damaged  or other defects are  found. 11. Inspect  serrations  (11)  around  port  (8)  for condition.  If  damaged,  replace  component. 12. Plug  port  (8) to  prevent  fluid  contamination. 13. Inspect  Rosan  fitting  (6) for cleanliness. 14. Ensure  lockring  (1) is not  cocked  on  fitting  (6). 15. Ensure  threads  and  fitting  serrations  (9) are  not damaged. 16. Remove  old  packing  (12) from  fitting  (6). 17. Inspect  packing  (12) contact area.   No  damage is  allowed. 18. Inspect  metal-to-metal  sealing  surfaces located immediately  above  packing  contact  area  for scratches  or  rough  spots.  None  are  allowed. INSTALLATION 19. Select packing  installation  tool  (13) from  table  1, and  packing  (12)  from  table  2. 20. Place  packing  (12) on  tool (13).  Place  installation tool  over the  port  thread  of fitting  (6). 21. Submerge  tool  (13) and  packing  (12) in  hydraulic fluid  (E199). 22. Slide  packing  (12) over tool  (13) and  onto  fitting (6).   Ensure  that  packing  (12) is  not twisted  and is  properly seated  in  groove  (5). 23. Remove  packing  installation  tool. 7-48