TM  55-1520-240-23-6 7-6 REPLACE  ROSAN ADAPTERS  AND  REDUCERS (Continued) 7-6 REMOVAL 1. Clean  surrounding  area.   Use  dry  cleaning solvent  (E162). 2. If  sealant  has been  used  to  cover lockring  (1), carefully  remove  sealant. 3. If reinstalling  same  fitting  index mark  lockring  (1) position.   Use  marking  pen. 4. Select proper lockring  removal tool  from  table  1. 5. Spread  puller  halves  (2)  by retracting  sleeve  (3) until  pin  (4)  bottoms  in  groove  (5). 6. Place  tool  over  Rosan  fitting  (6).   Close  puller halves (2)  over groove  (5) of lockring  (1).  Slide sleeve  (3) over  puller halves.   Check for  proper engagement with  lockring  groove. Be  sure  to  pull  lockring  (1)  straight and  only  enough  to  clear lockring serrations. 7. Turn  bolt  (7) clockwise  while  holding  sleeve  (3). This will  pull  lockring  out  of port  (8).   When  the external serrations  of  lockring  (1)  clear the  port, stop  turning  bolt. 8. Loosen  bolt  (7),  lift  sleeve  (3),  and  free  puller halves (2).  Remove  tool from  Rosan  fitting  (6). 7-46