TM  55-1520-240-23-6 7-5 REPAIR  PERMASWAGE  PLUMBING (Continued) 7-5 NOTE Swaging  dies make  ridges on  swaged fitting.  Check after-swage  dimensions between  ridges. 33. Inspect  swaged  end  with  appropriate  size go-no-go  inspection gage according to  illustration of after-swage  dimensions.  If gage  does  not  fit, fitting  may be  reswaged  only once.  Repeat steps 27  thru  33. 34. If  swaging  operation  was  done  off  aircraft, position  and  attach  separable  fitting  to component.   Align  mating  ends  and  position union  fitting.   Torque  fitting  to  its  final  torque, making  sure  fixed  portion  of  fitting  is  held stationary. 35. With  union  fitting  positioned  correctly,  repeat steps 24  thru  31  for  both  ends of fitting. 7-39