TM  55-1520-240-23-6 7-5 REPAIR  PERMASWAGE  PLUMBING (Continued) 7-5 23. Connect the  hydraulic pressure line from portable hydraulic  power  supply  to  fitting  on  base  of swaging  tool. 24. Set selector  valve  on  power supply to  EXHAUST to  relieve  all  line  pressure. If you  do  not  tighten  the  knurled  nut against  the  yoke,  the  yoke  assembly will  fail.   You  may  need  to  rotate  the yoke  180º  to  obtain  a  snug  fit. 24.1. Slide  square  portion  of  power  unit  into  yoke assembly.   Tighten  knurled  nut  snugly  against yoke. 25. Install  set  of  die  blocks in  swaging  tool.  Position tool below  level  of  power supply.  These  steps will prevent  air from  getting  in  the  hose  and  power supply.  Cycle  power supply  to  2000 psi followed by EXHAUST,  two  or  three  cycles to  bleed  air from  cylinder. NOTE Some  separable  fittings  are  swaged without locators. 26. See  chart  of  swage  tool  envelopes  to  select correct upper  and  lower  die  block assemblies for  size  of  fitting  to  be  swaged.   Insert lower  die block  with  correct fitting  locator into  tool.  When properly  inserted,  filling  locator is  on  opposite end  of  tool  relative  to  latch. 27. Place  swaging  tool  and  dies  over  separable fitting.   Make  sure  fitting  is  positioned  properly. Refer  to  figure  showing  acceptable  limits of tube insertion  into  union.  Push  up  latch  to  lock  dies in  place. 28. Position  face  of  swaging  tool  against  location mark on  tube.  Outer edge  of latch must  fall  within location  mark.  Tube  insertion  must  be  as  shown in  illustration  of  tube  insertion  limits. 29. Set selector valve to appropriate hydraulic output. 30. Actuate  swaging  tool  with  5,000  to 5,500  psi hydraulic  pressure.   If  shop  air  input  is  not available,  use  hand  pump. 31. Set  selector  valve  to  EXHAUST  to  relieve pressure  completely. 32. Slide  open  latch  and  remove  swaging  tool  from swaged  joint. 7-37