TM  55-1520-240-23-6 7-5 REPAIR  PERMASWAGE  PLUMBING (Continued) 7-5 PREPARE  REPLACEMENT  TUBE 16. Select  a  piece  of  tube  of  correct  length.   Tube shall be  the  same  as  that  being  replaced. 17. Bend  replacement  tube  to  shape  of  original tubing  leaving  some  excess  for  trim  at  both  ends. Remove  all  burrs.  (Refer  to  steps  10  thru  15.) Do  not  place  fitting  over  tube  end until  tube  end  is  properly  deburred. Damage  to  fitting  may  result. 18. Trim  the  fitting  end  of  the  tube.  (Refer  to  steps  4 thru  9.)   Place  fitting  over  tube  to  compare  length to  original  fitting  and  tube. 19. Install  fitting  onto  the  applicable  component. Position  tube  within  fitting,  aligning  the  other end  of  tube  with  mating  tube.  Remove  tube  and trim  the  other  end  as  required.   (Refer  to  steps 4  thru  9.)   The  maximum  gap  allowed  between mating  tubes  is  0.30 inch.  See  figure  for  allowing mismatch. 20. Remove  all  burrs  from  tube.   (Refer  to  steps  10 thru  15.) 7-34