TM  55-1520-240-23-6 7-5 REPAIR  PERMASWAGE  PLUMBING (Continued) 7-5 CUT TUBE 4. Select  appropriate  chipless  cutter  (1)  for  size of  tube  (2).   Check  that  ratchet  handle  (3)  is operating  freely and  cutter  wheel  (4)  is  clear  of cutter  head  opening.  Make  sure  cutter  is clean and  properly  lubricated.   See  step  3  for  correct tube  and  fitting  clearance. 5. Rotate  the  cutter  head  (5)  to  accept  tube  (2). Locate  cutter  (1)  in  cutting  position  on  tube.  Tube shall  be  centered  on  two  rollers  (6)  and  cutter wheel  (4). Overtorquing  soft  tubing  will  cause  a large  burr.   Overtorquing  hard  tubing can  damage  the  cutter  wheel. 6. Tighten  drive  screw  (7)  until light  contact is made on  tube  (2)  by cutter  wheel  (4).  Tighten  screw  an additional 1/8  to 1/4 turn.  Do  not overtorque. 7. Rotate  ratchet handle  (3)  thru  arc of  clearance until  there  is  noticeable  ease  of  rotation. 8. Tighten  screw  (7)  an  additional  1/8 to 1/4  turn. Repeat step  7  until  cut  is  complete. 9. Check  remaining  section  of tube  (2).  Cut shall  be square  to  tube  centerline  within  1/2º. 7-31