TM  55-1520-240-23-6 7-5 REPAIR  PERMASWAGE  PLUMBING 7-5 INITIAL  SETUP Applicable Configurations: All Tools: Hydraulic  Repairer’s Tool  Kit, NSN 5180-00-323-4891 Permaswage  Tube  Repair Kit, D1202C-15-H10,  NSN 5180-01-115-7008 Portable  Hydraulic Power Supply Materials: Hydraulic  Fluid  (E199) Gloves  (E184.1) Marking  Pen  (E271.2) Parts: Hydraulic  Tube  and  Fittings, As  Required Personnel  Required: Aircraft  Pneudraulics  Repairer References: TM  55-1520-240-23P Equipment  Condition: Applicable  System  Drained Hydraulic Line  to  be  Repaired  Disconnected  from Structure Applicable  Work  Platforms or Access Panels Open (Task  2-2) General  Safety  Instructions: Hydraulic  fluid  (E199)  is toxic.   It  can irritate  skin  and  cause  burns.   Avoid inhaling.   Use  only  with  adequate ventilation.   Avoid  contact  with  skin, eyes, or clothing.  In  case  of contact, immediately flush  skin  or eyes  with water  for  at  least  15  minutes.  Get medical  attention  for eyes. 7-27