TM  55-1520-240-23-6 7-4.2 TUBE  BENDING  (AVIM) (Continued) 7-4.2 16. Check  bends  in  tube  (1)  with  micrometer  as follows: a. Measure  and  record  maximum  outside diameter  (OD). b. Measure  and  record  minimum  OD. NOTE Operations  of steps c,  d, and  e  can  be expressed  as  follows: ( ) c. Subtract OD  of step  16b from OD  of step  16a. d. Divide  result found  in  step  16c  by  average (nominal)  OD  of tube  (1). e. Multiply  result  found  in  step  16d  by  100. f. Result found  in  step  16e  is percent of ovality. 17. Acceptable  level of tube  ovality or  flatness  shall be  5  percent  maximum. Solvent  (E161)  is  combustible  and toxic.   It can  irritate  skin  and  cause burns.   Use  only  with  adequate ventilation, away from  open  flame.  In case  of  contact,  immediately  flush skin  or  eyes  with  water  for  at  least 15  minutes.   Get  medical  attention for  eyes. 18. Clean  tube  (1).  Use  solvent  (E161). Propelled  debris  can  cause  injury  to eyes.   Use  source  of compressed  air under  30 psi  and  eye  protection  to prevent  injury  to  personnel. 19. Dry tube  (1)  with  low  pressure  compressed  air. Wear  goggles to  protect eyes. 20. Inspect  tube  (1).   There  shall  be  no  wrinkles or  kinks  deeper  than  1  percent  of  nominal OD.  There  shall  be  no  scratches  deeper  than 5  percent. FOLLOW-ON MAINTENANCE: Install  end  fittings and  sleeves as required  (Task 7-5). Apply  appropriate  identification  markings  (APP E-50). END  OF  TASK 7-26