TM  55-1520-240-23-6 7-1 FLIGHT CONTROL HYDRAULIC SYSTEM (Continued) 7-1 Reservoir Cooler Fluid  storage  and  cooling  for  each  system  is  provided  by an  integrated  reservoir  cooler  module  with  a  separate fan.   The  reservoir  section  of  the  module  stores  fluid for  system  operation.   The  cooler  is  mounted  on  top  of the  reservoir.   It  is  connected  by  flexible  ducting  to  a fan  that  is  activated  by  a  thermal  switch  in  the  cooler. Sensors  in  the  unit  send  information  on  fluid  level  and temperature  to  the  maintenance  panel  in  the  ramp  area. An  indicating  rod  on  the  reservoir  provides  another indication  of  system  fluid  level. NO  BREAK  -  WORK  HARDER The  reservoir  cooler  and  fan  for  the  No.  1  system  are  in the  forward  fairing,  aft  of  the  forward  transmission.  The No.  2  system  module  is  in  the  aft  pylon  on  the  left  side. Lower  Controls Modules A  lower  controls  module  in  each  system  reduces hydraulic  pressure  to  the  integrated  lower  controls actuators  (ILCA)  from  3,000  to 1,500 psi. NO  BREAK  -  WORK  HARDER A  solenoid  valve  in  each  module  shuts  off  hydraulic pressure  to  the  AFCS  extensible  links  in  each  ILCA.  It is  actuated  by  either  manual  or  automatic  shutdown  of the  AFCS. NO  BREAK  -  WORK  HARDER The  modules  for  both  systems  are  located  in  the  upper part  of  the  flight  controls  closet.   The  No.   1  system module  is  at  sta.  100.  The  No.  2  module  is  at  sta.  95. 7-6