TM  55-1520-240-23-4 5-5 PRESSURE  TEST ROTARY-WING HEAD  SEALS  AND  PACKINGS 5-5 INITIAL  SETUP Applicable  Configurations: All Tools: Powertrain  Repairer’s  Tool   Kit,   NSN 5180-00-003-5267 Pump,  Manual  Inflating Dial Indicating  Pressure  Gage,  0  to  30  Psi Air  Hose,  4  Feet Long  (APP  E-4) Stopwatch Torque  Wrench,  5  to  50  Inch-Pounds Torque  Wrench,  30  to  150  Inch-Pounds Pressurizing  Fitting  (APP  E-4) Materials: Lockwire  (E231) Parts: Packings Personnel  Required: Aircraft  Powertrain  Repairer  (2) Inspector References: TM  55-1520-240-23P Appendix  E Equipment  Condition: Battery Disconnected  (Task  1-39) Electrical  Power  Off Hydraulic  Power  Off One  Forward  and  One  Aft  Rotary-Wing  Blade Tied-Down  (Task  1-26) Work  Platform  Open  (Task  2-2) Pressure  Test  Setup General  Safety Instructions: Release  pressure  at fittings  carefully; otherwise,  lubricating  oil  can  spray out.  Lubricating  oil  can  be  harmful  to nose, eyes,  or  mouth. 5-26