TM  55-1520-240-23-4 5-3 REMOVE ROTARY-WING  HEAD FROM  SHIPPING  CONTAINER (Continued) 5-3 Be  careful  when  releasing  air under pressure;  wear  goggles.   Personal injury  can  result. 1. Press air  valve  (1) in  cover (2) of  container (3). 2. Turn  cap  (4)  counterclockwise.   Remove rotary-wing  head  log  from  receptacle  (5). 3. Remove  24  nuts  (6),  lockwashers  (7),  bolts  (8), and  washers  (9) from  flanges  of container (3). Remove  cover  (2). 4. Remove  desiccant (10) from  basket (11). 5-16