INSTALL FIRE  DETECTION SENSING ELEMENT (Continued)
Up
TM-55-1520-240-23-10 UH-1H/V and EH-1H Aircraft Manual
Next
REPLACE  FIRE  PULL  HANDLE  LAMP

TM  55-1520-240-23-10 12-13 INSTALL  FIRE  DETECTION  SENSING ELEMENT (Continued) 12-13 34. Remove  caps  from  cable  (18)  and  connector (19)  on  fuselage.  Insert  connector  (20)  through bracket  (9). 35. Install  and  lockwire  nut  (21).   Use  lockwire (E231). 36. Make  sure  insert  (10)  is  in  connectors  (19  and 20),  white  dot  (12)  first. 37. Connect cable  (18) to connector (19)  on  fuselage. Torque  cable  to  65 inch-pounds. 38. Connect  element  (16)  to  connector  (20)  at bracket (9).  Torque  element to  65 inch-pounds. 39. Install  bushing  (6)  on  cable  (18)  at clamp  (2). 40. Press cable  (18)  and  bushing  (6)  into  clamp  (2). Bushing  shall  be  centered  in  clamp. 41. Lock  clamp  (2)  with  fastener  (7). INSPECT Do  not  allow  element  to  touch  or chafe  on  engine  or  engine  cover. Element  can  be  damaged  by chafing. A  damaged  element  can  cause  a false  fire  indication  or  an  inoperative fire  detection  system  resulting  in equipment  damage  and  injury  to personnel. 42. Check  elements  (1, 8,  and  16).  Elements  shall not  chafe  or  touch  engine  (5)  or  engine  cover (21). FOLLOW-ON  MAINTENANCE: Close  engine  access  cover  (Task  4-50). Close  engine  work  platform  (Task 2-2). Perform  operational  check  of  fire  detection  system (TM  55-1520-240-T). END  OF  TASK 12-42

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing