REPLACE  LOCKED-IN  STUD (AVIM) (Continued)
Up
TM-55-1520-240-23-1 UH-1H/V and EH-1H Aircraft Manual
Next
REPLACE  SCREW-THREAD  INSERT (AVIM)

TM  55-1520-240-23-1 1-15 REPLACE  LOCKED-IN  STUD (AVIM) (Continued) 1-15 18. Coat lock  ring  (4)  with  primer  (E292.1).   Wear gloves (E184.1). 19. Position  lock ring  (4)  over  stud  (2),  undercut  (9) toward  housing  (1).   Align  serrations (10)  with serrations  on  housing  and  flange  (6)  as  much as  possible. 20 Drive  lock  ring  (4)  around  flange  (6)  and  into housing  (1).  Use  special  drive  tool  (11). For Stud: Use Tool: MS51989-104 S91D-10 MS51989-105 S101D-12 MS51989-106 S111D-12 MS51989-107 S121D-12 MS51992B-504-13 SF5902-4D SHF101-9SA(8)A S101D-12 ST-10045 S101D-12 21. Remove  any  protective  covering  from  area  of stud  (2)  installation. INSPECT NO  BREAK  -  WORK  HARDER NO  BREAK  -  WORK  HARDER FOLLOW-ON  MAINTENANCE: None END  OF  TASK 1-26