1-5.  SOURCE ACTUATION

TM 5-6635-386-12&P 1/4, 1/2, 1 or 2 = SIMULTANEOUS COUNT OF BOTH CHANNELS TEST + ANY DISPLAY = DISPLAY TEST (88888) TEST + LOCK = INTERNAL CHECK (65536) (16384 after 7/78) STD + LOCK = STANDARD COUNT (4 MIN) D-ONLY or M-ONLY = ONLY COUNT ONE CHANNEL NOTE Some testers do not have the D-only or M-only keys. CLEAR = STOP COUNT (Does not reset to zero) D-DATA or M-DATA = DISPLAY LAST FIELD COUNT D-STD or M-STD = DISPLAY LAST STD or TEST COUNT NOTE All  count  periods  are  "normalized"  to  a  common  time base of 1/4 minute to reduce operator work in the field. After        approximately        July        1978,    Internal        Check (TEST+LOCK) will count only 1/4 minute and will display 16384. Both   TEST/LOCK   and   STD/LOCK   count   into   all   four channels as a cross check for counting accuracy. If    nothing    at    all    happens    when    the    touchkeys    are pressed,  the  batteries  are  completely  discharged  or  are disconnected.    See  Para  1-1.    (General  Operation)  and also Para 3-5.  (Battery Replacement). If a mistake is made in starting the count, clear the tester with the CLEAR key and restart the sequence.  This will clear  all  stored  commands.    If  an  erroneous  time  cycle was  pressed,  it  is  necessary  only  to  press  the  correct touchkey to restart on the correct time cycle. To  take  a  density  count  only  and  NOT  take  a  moisture count, press D-ONLY.  The previous moisture count will be stored.  The D-ONLY command will erase at the end of     the     count     cycle.          M-ONLY     follows     a     similar circumstance. The   tester   will   automatically   take   its   own   4   minute standard     count,     if     STD     and     LOCK     are     pressed simultaneously.    All  four  memories  are  erased  and  the standard count is fed into all four memories See Para 1- 7, Standard Count. The tester may be internally checked by pressing TEST and LOCK simultaneously.  The tester will count for one minute,   providing   a   fixed   time   base   pulse   to   all   four memories.  All four memories should read  65536  at  the end  of  the  count  period.    (1/4  minute  and  16384  after 7/78). The  LOCK  key  prevents  an  accidental  field  erasure  of the standard count memories by an inadvertent pressing of the STD or TEST keys. 1-7

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing