TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 4.  (Cont) c. Defective a. Set multimeter to ac volts.  Connect leads to electronics P1-9 (+) and P1-23 (-). assembly. b. If meter indicates less than 10 vac, replace the electronics assembly. CAUTION Inner  enclosure  is  heavy.    Use  caution  when  removing from outer enclosure. (1)   To remove electronics assembly, loosen collar on connector P2.  Turn metal tab 90 degrees and disconnect P2 from J2.  Tag and disconnect wires that run from terminal boards to conduit.  Slide the inner enclosure out of the outer enclosure.  Place inner en- closure on bench.  Remove screws, lock washers, and washers and disconnect con- nector J1 from P1.  Remove electronics assembly mounting screws from rear of of inner enclosure.  Remove electronics assembly. (2)   To install new electronics assembly, posi- tion electronics assembly on inner enclo- sure.  Install mounting screws through rear of inner enclosure.  Connect J1 to P1 and install screws, lock washers, and washers.  Slide inner enclosure into outer enclosure.  Route wires through closure. Connect wires that run from terminal boards to conduits.  Align notch on P2 to J2.  Connect P2 to J2.  Lock metal tabs together and tighten collar on connector P2. d. Broken wires, a. Set multimeter to ac volts.  Connect leads to P1-9 loose con- (+) and P1-23(-). nections, or bent b. If meter indicates 12  +2 vac, inspect wiring from pins. P1 to TB3 and T2 for broken wires, loose con- nections, or bent pins. c. Connect leads to TB3-6 and TB3-7.  If meter indi- cates 18 +2 vac, inspect wiring from T2 to TB3 and the speaker. 5-26

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing