Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 3.  (Cont) h. (Cont) b. If meter indicates less than 21 vdc, replace battery. (1)   To remove battery, disconnect battery wires from battery.  Remove screw and washer from battery clamp bracket and remove battery. (2)   To install new battery, position battery and battery clamp bracket.  Install screw and washer.  Connect battery wires to battery. 4.  Low a. Defective a. Interrupt ac power from Control Unit.  Set multi- Audible battery. meter to dc volts.  Connect positive meter lead to Alarm red battery terminal and negative meter lead to sound black battery terminal.  Ensure that power level. switch S3 is set to POWER ON.  Meter should indicate 21 vdc or more. b. If meter indicates less than 21 vdc, replace battery. (1)   To remove battery, disconnect battery wires from battery.  Remove screw and washer from battery clamp bracket and remove battery. (2)   To install new battery, position battery and battery clamp bracket.  Install screw and washer.  Connect battery wires to battery. b. Defective a. Set multimeter to ac volts.  Connect leads to power trans- TB3-1(+) and TB3-2(-). former T1. b. If meter indicates less than 60 vac, replace defec- tive power transformer. (1)   To remove transformer, note length and con- nection location of transformer wires.  Dis- connect wires.  Remove mounting screws and washers.  Connect transformer wires. (2)   To install new transformer, cut transformer wires to proper length and install crimp terminals.  Position transformer on inner enclosure and install mounting screws and washers.  Connect transformer wires. 5-25

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing