Troubleshooting Procedures - Continued
Up
TM-5-6350-264-14P-9 Audible Alarm (AA) Model BZ-204/FSS9(V) Manual
Next
Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 3.  (Cont) f. (Cont) b. If the multimeter indicates more than 0 ohms at any of the above points, inspect wiring for broken or loose connections, inspect plugs for bent or broken pins, and inspect conduit for poor connections. g. Defective a. Ensure that power switch S1 in Control Unit is power trans- turned off.  Slide inner enclosure part way out. former T1. Remove screws that secure switch bracket. Lower switch bracket to gain access to terminal on switch S3.  Ensure that switch S3 is on.  Set multimeter to ohms.  Connect meter leads to S3-1 and 2 (red wires).  Note meter indication. Connect meter leads to S3-3 and 4 (black wires). Note meter indication. b. If meter indicates 0 ohms, inspect wiring for bro- ken or loose connections at the following points: fuse F1 to S3-4; S3-3 to T1; T1 to TB3-1 and 2; TB3-1 and 2 to P1-l and 2; battery red lead to S3-2; S3-1 to P1-19. c. If wiring connections are good, replace power trans- former. (1)   To remove transformer, note length and con- nection points of transformer wires.  Discon- nect wires.  Remove transformer. (2)   To install new transformer, cut transformer wires to proper length and install crimp lugs. Position transformer on inner enclosure and install mounting screws and washers.  Con- nect transformer wires. h. Defective a. Interrupt ac power from Control Unit.  Set multi- battery. meter to dc volts.  Connect positive meter lead to red battery terminal and negative meter lead to black battery terminal.  Ensure that power switch S3 is set to POWER ON.  Meter should in- dicate 26 vdc or more. 5-24

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing