TM-5-6350-264-14P-9 Audible Alarm (AA) Model BZ-204/FSS9(V) Manual
Next
Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 3.  (Cont) e.  (Cont) should indicate 0 ohms.  Release the switch plunger.  Meter should indicate more than 100,000 ohms. b. If these indications are not correct, replace tam- per switch. (1)   To remove door tamper switch, remove tam- per switch support mounting screws.  Push switch through outer enclosure.  Tag wires. Use a soldering iron of 50 watts maximum to unsolder wires.  Unscrew switch from switch support and remove switch. (2)   To install new door tamper switch, screw switch into switch support.  Solder wires. Position switch and support on outer enclosure.  Install tamper switch support mounting screws. (3)   To remove pry-off tamper switch, remove mounting screws from tamper switch brack- et.  Remove hex nut and push switch through switch bracket.  Tag wires.  Use a soldering iron of 50 watts maximum to un- solder wires.  Remove pry-off tamper switch. (4)   To install new pry-off tamper switch, sold- er wires and position switch in switch brack- et.  Install hex nut and snap on button cap. Position switch and switch bracket on inner enclosure and install mounting screws. f. Poor or unbro- a. Set multimeter to ohms.  Connect meter leads to ken ground each of the following points: connections. TB2-2 to outer enclosure; TB2-2 to TB3-3; TB2-2 to P1-3, 4, 16, 17; TB2-2 to P1-23; TB2-2 to battery negative lead. 5-23

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing