Troubleshooting Procedures - Continued
Up
TM-5-6350-264-14P-9 Audible Alarm (AA) Model BZ-204/FSS9(V) Manual
Next
Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 2.  (Cont) b. (Cont) bracket.  Tag wires and use a soldering iron of 50 watts maximum to unsolder wires. Remove pry-off tamper switch. (4)   To install new pry-off tamper switch, solder wires and position switch in switch bracket. Install hex nut and snap on button cap.  Po- sition switch and switch bracket on inner enclosure mounting bracket and install mounting screws. c. Intermittent a. Set multimeter to dc volts.  Connect positive meter continuity lead to TB2-3 and negative meter lead to TB2-2. between inner and outer b.  If meter indication changes during periods of nui- enclosures. sance alarms to below 1 vdc, place positive meter lead on inner enclosure and negative meter lead on outer enclosure.  Ensure good contact is made at the outer enclosure. c. If meter indication drops below 0.9 vdc, turn power switch S3 to POWER OFF.  Remove P2 from J2. d. Set multimeter to ohms.  Connect meter leads to inner and outer enclosure. e. If meter indicates less than 13,000 ohms, inspect enclosures for foreign matter, conduit contacting both enclosures, frayed wires, leaky battery, or any other material that will allow continuity between enclosures. d.  Defective a. Set multimeter to ohms.  Connect meter leads to capacitor. inner and outer enclosure. b. If meter indicates more than 13,000 ohms, tag, remove, and isolate the yellow wires (-) from C15 and C16. c. Connect leads to inner enclosure and negative ter- minal of C15, then to inner enclosure and nega- tive terminal of C16. 5-18

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing