TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 1.  (Cont) d.  (Cont) enclosure out of the outer enclosure.  Place inner enclosure on bench.  Remove screws, lock washers, and washers and disconnect connector J1 from P1.  Remove mounting screws from    rear    of    inner    enclosure    and    remove    electronics assembly. (2)   To  install  new  electronics  assembly,  position  assembly on  inner  enclosure.    Install  mounting  screws  through rear  of  inner  enclosure.    Connect  J1  to  P1  and  install screws,    lock    washers,    and    washers.        Slide    inner enclosure  into  outer  enclosure.    Route  wires  through hole in rear of inner enclosure.  Connect wires that run from  terminal  boards  to  conduits.    Align  notch  on  P2 with J2 and connect P2 to J2.  Lock metal tabs together and tighten collar on connector P2. e. Defective a. Set multimeter to dc volts.  Connect positive meter lead to tamper P1-24 and negative meter lead to TB2-2. switch. b. If meter indicates 6 +0.5 vdc, connect positive meter lead to P1-12 and negative meter lead to TB2-2. c. If  meter  indicates  less  than  1  vdc,  turn  power  switch  S3  to POWER OFF.  Remove P2 from J2. d. Set the multimeter to ohms.  Connect leads to tamper switch terminals that have wires connected. (1)   Depress  the  switch  plunger.    Meter  should  indicate  0 ohms. (2)   Release the switch plunger.  Meter should indicate more than 100,000 ohms. e. If meter indications are not correct, replace tamper switch. 5-13

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing