Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 1.  (Cont) d.  (Cont) switch  S3.    Ensure  that  switch  S3  is  on.    Set  multimeter  to ohms.  Connect meter leads to S3-1 and 2 (red wires).  Note meter indication.  Connect meter leads to S3-3 and 4 (black wires).  Note meter indication. b. If meter indicates 0 ohms, inspect wiring for broken or loose connections at the following points: fuse F1 to S3-4; S3-3 to T1; T1  to  TB3-1  and  2;  TB3-1  and  2  to  P1-1  and  2;  battery red lead to S3-2; S3-1 to Pl-19. c. If wiring connections are good, replace power transformer. (1)   To   remove   transformer,   note   length   and   connection points of transformer wires.  Disconnect wires.  Remove mounting screws and washers.  Remove transformer. (2)   To   install   new   transformer,   cut   transformer   wires   to proper length and install crimp lugs.  Position transformer on   inner   enclosure   and   install   mounting   screws   and washers.  Connect transformer wires. d. Set  multimeter  to  ac  volts.    Disconnect  P1/J1  and  connect meter leads to P1-i and P1-2.  Turn on switch S3.  If voltage is not within tolerance, 68 +7 vac),replace power transformer. If voltage is within tolerance, replace electronics assembly. CAUTION Inner  enclosure  is  heavy.    Use  caution  when  removing from outer enclosure. (1)   To    remove    electronics    assembly,    loosen    collar    on connector    P2.        Turn    metal    tab    90    degrees    and disconnect  P2  from  J2.    Tag  and  disconnect  wires  that run from terminal boards to conduit.  Slide the inner 5-12

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing