Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page  Title: Troubleshooting Procedures - Continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Troubleshooting Procedures - Continued
Up
TM-5-6350-264-14P-9 Audible Alarm (AA) Model BZ-204/FSS9(V) Manual
Next
Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 1.  (Cont) b. (Cont) leads to inner enclosure and negative terminal of C15.  Note indication.      Connect   meter   leads   to   inner   enclosure   and negative  terminal  of  C16.    Meter  should  indicate  less  than 100,000  ohms  in  both  tests.    Meter  may  not  give  correct indication immediately. i. If  either  indication  is  greater   than   100,000   ohms,   replace electronics assembly. CAUTION Inner  enclosure  is  heavy.    Use  caution  when  removing from outer enclosure. (1)   To remove electronics assembly, loosen collar on connector P2.  Turn metal tab 90 degrees and disconnect P2 from J2. Tag  and  disconnect  wires  that  run  from  terminal  boards  to conduit.  Slide the inner enclosure out of the outer enclosure. Place   inner   enclosure   on   bench.      Remove   screws,   lock washers, and washers and disconnect connector J1 from P1. Remove  mounting  screws  from  rear  of  inner  enclosure  and remove electronics assembly. (2)   To  install  new  electronics  assembly,  position  assembly  on inner  enclosure.      Install   mounting   screws   through   rear   of inner  enclosure.    Connect  J1  to  P1  and  install  screws,  lock washers,   and   washers.      Slide   inner   enclosure   into   outer enclosure.        Route    wires    through    hole    in    rear    of    inner enclosure.    Connect  wires  that  run  from  terminal  boards  to conduits.    Align  notch  on  P2  with  J2  and  connect  P2  to  J2. Lock metal tabs together and tighten collar on connector P2. j. Reconnect   leads   to   negative   terminals   of   C15   and   C16. Turn  on  switch  S3  on  power  supply.    Set  multimeter  to  ac volts.  Connect positive lead to P1-l and negative lead to P1- 2. 5-9

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing