TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 1.  (Cont) b. (Cont) e. If meter indicates 5 +0.5 vdc, inspect wiring from TB2 to P1 for broken or loose connections.  Repair or replace defective wiring. f. If  meter  indicates  less  than  1  vdc,  connect  positive  meter lead to P1-24 and negative meter lead to TB2-2. g. If  meter  indicates  less  than  1  vdc,  replace  the  electronics assembly. CAUTION Inner  enclosure  is  heavy.    Use  caution  when  removing from outer enclosure. (1)   To remove electronics assembly, loosen collar on connector P2.  Turn metal tab 90 degrees and disconnect P2 from J2. Tag  and  disconnect  wires  that  run  from  terminal  boards  to conduit.  Slide the inner enclosure out of the outer enclosure. Place   inner   enclosure   on   bench.      Remove   screws,   lock washers, and washers and disconnect connector J1 from P1. Remove  mounting  screws  from  rear  of  inner  enclosure  and remove electronics assembly. (2)   To  install  new  electronics  assembly,  position  assembly  on inner  enclosure.      Install   mounting   screws   through   rear   of inner  enclosure.    Connect  J1  to  P1  and  install  screws,  lock washers,   and   washers.      Slide   inner   enclosure   into   outer enclosure.        Route    wires    through    hole    in    rear    of    inner enclosure.    Connect  wires  that  run  from  terminal  boards  to conduits.    Align  notch  on  P2  with  J2  and  connect  P2  to  J2. Lock metal tabs together and tighten collar on connector P2. h. Turn off switch  S3  on  power  supply.    Set  the  multi-meter  to ohms.  Tag, remove, and isolate terminals of C15 and C16. Set multimeter to ohms and connect 5-8

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing