Table 5-1 Troubleshooting Procedures
Up
TM-5-6350-264-14P-9 Audible Alarm (AA) Model BZ-204/FSS9(V) Manual
Next
Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T.O. 31S9-2FSS9-1-9 Table 5-1.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 1.  (Cont) b. Defective a. Turn on switch S3 on power supply.  Set multimeter electronics to dc volts.  Connect positive meter lead to TB2-1 assembly and negative meter lead TB2-2.  Meter should in- or power dicate less than 1 vdc. transformer. b. If meter indicates 1 vdc or more replace the elec- tronics assembly. CAUTION Inner  enclosure  is  heavy.    Use  caution  when  removing from outer enclosure. (1) To    remove    electronics    assembly,    loosen    collar    on connector    P2.        Turn    metal    tab    90    degrees    and disconnect  P2  from  J2.    Tag  and  disconnect  wires  that run   from   terminal   boards   to   conduit.      Slide   the   inner enclosure   out   of   the    outer    enclosure.        Place    inner enclosure on bench.  Remove screws, lock washers, and washers and disconnect connector J1 from P1.  Remove mounting    screws    from    rear    of    inner    enclosure    and remove electronics assembly. (2) To  install  new  electronics  assembly,  position  assembly on inner enclosure.  Install mounting screws through rear of inner enclosure.  Connect J1 to P1 and install screws, lock  washers,  and  washers.    Slide  inner  enclosure  into outer  enclosure.    Route  wires  through  hole  in  rear  of inner  enclosure.    Connect  wires  that  run  from  terminal boards   to   conduits.      Align   notch   on   P2   with   J2   and connect P2 to J2.  Lock metal tabs together and tighten collar on connector P2. c. Set  multimeter  to  dc  volts.    Connect  positive  meter  lead  to TB2-3   and   negative   meter   lead   to   TB2-2.      Meter   should indicate 5 i0.5 vdc. d. If  meter  indicates  less  than  1  vdc,  connect  positive  meter lead to P1-13 and negative meter lead to TB2-2. 5-7

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing