Figure 5-1.  Audible Alarm with Troubleshooting Test Points

TM 5-6350-264-14&P-9 NAVELEX EE 181-AA-OMI-100/E121 DZ-204 T. O.  31S9-2FSS9-1-9 Turn the operating mode switch to ACCESS. (1) If    the    AA    is    silent,    put    on    ear protection   and   open   the   AA   door Pull the TAS plunger all the way out. Remove screws that secure faceplate,     and     remove     faceplate Turn off power switch located in the upper   left   corner   of   the   AA   Tag, disconnect,    and    insulate    speaker wire from TB3-7. (2) If  the  AA  continues  to  sound,  tag, disconnect,  and  insulate  green  wire (from  status  processor)  from  TB4-1 in the Control Unit Install  a  jumper between TB4-4 and TB4-1 AA should    be     silenced     Put     on     ear protection   and   open   AA   door   Pull the   TAS   plunger   all   the   way   out Remove    screws    that    secure    the faceplate, and remove the faceplate. Turn off power switch located in the upper left corner of the AA.  Tag, disconnect,    and    insulate    speaker wire from TB3-7 in the Control  Unit, remove  the  AA  interconnecting  wire from  TB4-3  and  connect  a  jumper wire  from  TB4-4  and  TB43  Turn  on power    switch    in    AA.        The    AA speaker is now disabled and maintenance and troubleshooting may be performed. (3) When maintenance or troubleshooting has been completed,  turn  off  power  switch  in AA    In    the    Control    Unit,    remove jumper  wire  from  TB4-4  and  TB4-3 Connect  AA  interconnecting  wire  to TB4-3  In  the  AA,  connect  speaker wire to TB3-7;  turn  on  power  switch Install   and   secure   faceplate   Close door   on   AA   On   Control   Unit,   turn operating    mode    switch    to    TEST/ RESET and then to SECURE. g Inspect varistors for evidence of physical damage   or   overheating   Disconnect   one   lead from  each  varistor  from  TB1.  Set  multimeter  to ohms and connect one lead to each varistor lead Meter    should    indicate    over    100,    000    ohms. Check both varistors. h Refer  to  figure  5-1  for  all  test  points  found  in troubleshooting  table  5-1  Figure  5-2  is  a  wiring diagram    of    the    Audible    Alarm    Step-by-step troubleshooting   procedures,   including   Trouble, Probable    Cause,    and    Corrective    Action,    are listed in table 5-1. 5-3

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing