Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page  Title: Troubleshooting Procedures - Continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Troubleshooting Procedures - Continued
Up
TM-5-6350-264-14P-10 Alarm Set Control Manual
Next
Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-10 NAVELEX EE 181-AA-OMI-110/E121 C-9412 T.O. 31S9-2FSS9-1-10 Table 5-2.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 4. (Cont) c. Bad tamper a. Set multimeter to dc volts and connect circuitry positive meter lead to PC board A7-TP2 (telephone (red), and negative lead to chassis dialer). (ground). b. If meter indicates 18.5 to 21 vdc, ensure that there is a jumper between TB7, S-8 and S-9.  Set multimeter to ohms and connect leads to TB7, S- and S-9.  If meter indicates more than 0 ohms, replace jumper. c. If meter indicates 0 ohms, turn off switch S1 on power supply.  Use board ejector to remove PC board A7.  Connect meter leads to J7-1 and J7-7. d. If meter indicates more than 100, 000 ohms, inspect J12/P1, pins 19 and 34 for broken or loose wires.  Resolder any bad connections at P1, pins 19 and 34. e. If meter indicates 0 ohms at J7-1 and J7-7, replace PC board A7. To install new PC board, turn board so plastic ejector is toward top.  Align board with guides at top and bottom of status processor.  Slide board straight in until it contacts re- ceptacle at back of processor. Then press firmly on board until it seats completely in receptacle. f. Turn on switch S1 on power supply.  De- press TRANSMITTER RESYNC switch S2.  Wait about 5 minutes for system to stabilize.  During 5-minute stabilization period, check ower sup- ply.  Set multimeter to dc volts and connect negative lead to chassis (ground).  Connect positive lead to power supply, TB2-3.  Meter should indicate 20 +1 vdc.  Connect positive lead to TB2-S.  Meter should indicate 5-56

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing