Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-10 NAVELEX EE 181-AA-OMI-110/E121 C-9412 T.O. 31S9-2FSS9-1-10 Table 5-2.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 4.   (Cont) b.   (Cont) and bottom of status proces- sor.  Slide board straight in until it contacts receptacle at back of processor.  Then press firmly on board until it seats completely in receptacle. i. If meter indicates over 100, 000 ohms at J7-1 and J7-14, connect meter eads to J7-14 and TB4-3 in power supply. Meter should indicate 0 ohms. j. If meter indicates over 100,000 ohms, in- spect J12/P1, pin 17 for broken or loose connections.  Resolder any bad connections at P1, pin 17. k. Connect meter leads to J7-1 and TB4-2 in power supply.  Meter should indicate 0 ohms. l. If meter indicates over 100, 000 ohms, in- spect J12/P1, pin 34 for broken or loose connections.  Resolder any bad connections at P1, pin 34. m. Turn on switch S1 on power supply.  De- press TRANSMITTER RESYNC switch S2.  Wait about 5 minutes for system to stabilize.  During 5-minute stabilization period, check power sup- ply.  Set multimeter to dc volts and connect negative lead to chassis (ground).  Connect positive lead to power supply, TB2-3.  Meter should in- dicate 20 ± 1 vdc.  Connect positive lead to TB2-5.  Meter should indicate 5 ± 0.25 vdc.  Connect lead to TB2-2. Meter should indicate 28 +2 vdc.  Turn mode switch to TEST/RESET and then to SECURE. n. Reconnect Data Transmitter or Monitor Cabinet wires to TB6 S1-D and S1-DR. 5-55

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing