TM 5-6350-264-14&P-10 NAVELEX EE 181-AA-OMI-110/E121 C-9412 T.O. 31S9-2FSS9-1-10 Table 5-2.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 4.   (Cont) b.   (Cont) PC board A7.  Set multimeter to ohms and connect meter leads to TAS termi- nals which have wires attached.  Push TAS plunger all the way in, and then pull plunger all the way out.  Meter should indicate 0 ohms for both switch positions.  Depress TAS plunger and then release.  Meter should indicate over 100,000 ohms. d. If these meter indications are not correct, re- place TAS. (1) To remove TAS, remove screws that se- cure TAS to edge of CU housing. Loosen screws that secure crimp lugs to switch. (2) To install new TAS, slip crimp lugs un- der screw heads marked COM and NO on switch, and tighten screws. Insert switch through hole in edge of housing from the back, and in- sert screws from the front.  Tighten screws to secure switch. e. If meter indications are correct, pull TAS plunger all the way out.  Connect meter leads to J7-4 and J7-7.  Meter should indicate 0 ohms. f. If meter indicates over 100, 000 ohms, in- spect J12/P1, pins 18 and 19 for broken or loose wires.  Resolder any bad connections at P1, pins 18 and 19. g. If meter indicates 0 ohms at J7-4 and J7-7, connect a jumper wire in power supply from TB4-3 to TB4-2.  Connect meter leads to J7-1 and J7-14.  Meter should indicate 0 ohms. h. If meter indicates 0 ohms, replace PC board A7. To install new PC board, turn board so plastic ejector is toward top. Align board with guides at top 5-54

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing