Troubleshooting Procedures - Continued
Up
TM-5-6350-264-14P-10 Alarm Set Control Manual
Next
Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-10 NAVELEX EE 181-AA-OMI-110/E121 C-9412 T.O.  31S9-2FSS9-1-10 Table 5-2.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 2.   (Cont) d.   (Cont) m. If meter indicates 20 +1 vdc at TB2-3, turn off switch S1 on power supply.  Set multimeter to ohms and connect leads to TB2-3 and S3, terminal 2-4.  Meter should indicate 0 ohms. n. If meter does not indicate 0 ohms, inspect wires from TB2-3 to S3, terminal 2-4 for broken or loose connections.  Re- solder any bad connections. o. To reinstall PC board A8, turn off switch S1 on top of power supply, turn board so plastic ejector is toward top.  Align board with guides at top and bottom of status processor.  Slide board straight in until it contacts receptacle at back of processor.  Then press firmly on board until it seats completely in re- ceptacle. p. Turn on switch S1 on power supply.  De- press TRANSMITTER RESYNC switch S2.  Wait about 5 minutes for system to stabilize.  Turn mode switch to TEST/ RESET and then to SECURE. e.   Bad Pc a. Remove PC board A10. board A10. To remove PC board A10, turn off switch S1 on top of power supply. Place thumb or finger under board ejector and lift up until board pops out of receptacle at back of status processor.  Then grasp PC board and pull straight out. b. Turn on switch S1 on power supply.  De- press TRANSMITTER RESYNC switch S2.  Wait about 5 minutes for system to stabilize.  During 5-minute stabilization period, check power supply.  Set multi- meter to dc volts and connect negative lead to chassis (ground).  Connect posi- tive lead to power supply, TB2-3.  Meter should indicate 20 i1 vdc.  Connect positive lead to TB2-5.  Meter should 5-47

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing