Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-10 NAVELEX EE 181-AA-OMI-110/E121 C-9412 T.O.  31S9-2FSS9-1-10 Table 5-2.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 1. (Cont) f. (Cont) supply, TB2-3.  Meter should indi- cate 20 ± 1 vdc.  Connect positive lead to TB2-5.  Meter should indi- cate 5 ± 0.25 vdc.  Connect positive leads to TB2-2.  Meter should indi- cate 28 ± 2 vdc.  Turn mode switch to TEST/RESET and then to SECURE. f. If meter indicates 5 +0.25 vdc at S3, terminal 3-2, remove leads and set multimeter to ohms.  Re- move PC board A10. To remove PC board A10, turn off switch S1 on top of power supply.  Place thumb or finger under board ejector and lift up until board pops out of recep- tacle at back of status proces- sor.  Then grasp PC board and pull straight out. g. Connect meter leads to S3, terminal 3-4, and J10-11. h. If meter indicates more than 100, 000 ohms, inspect wires from S3, terminal 3-4 to J12/P1, pin 32, and from J12/P1, pin 32 to J10-11 for loose or broken connections.  Re- solder any bad connections on P1. i. If meter indicates 0 ohms, connect leads to J10-R and power supply TB4-1. j. If meter indicates more than 100, 000 ohms, inspect wires from J10-R to J12/P1, pin 30, and from J12/P1, pin 30 to TB4-1 for loose or broken connections.  Resolder any bad connections on P1. k. If meter indicates 0 ohms, connect leads to S3, terminal 3-4 and J10-4. Turn mode switch S3 to SECURE and then to ACCESS. 5-31

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing