Troubleshooting Procedures - Continued
Up
TM-5-6350-264-14P-10 Alarm Set Control Manual
Next
Troubleshooting Procedures - Continued

TM 5-6350-264-14&P-10 NAVELEX EE 181-AA-OMI-110/E121 C-9412 T.O.  31S9-2FSS9-1-10 Table 5-2.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 1. (Cont) b. (Cont) l. Turn on switch S1 on power supply.  De- press TRANSMITTER RESYNC switch S2.  Wait about 5 minutes for system to stabilize.  During 5-minute stabilization period, check power supply.  Set multi- meter to dc volts and connect negative lead to chassis (ground).  Connect posi- tive lead to power supply, TB2-3. Meter should indicate 20+1 vdc.  Con- nect positive lead to TB2-5.  Meter should indicate 5 +0.25 vdc.  Connect positive lead to TB2-2.  Meter should indicate 20 ± 2 vdc.  Turn mode switch to TEST/RESET and then to SECURE. c. Bad tamper cir.- a. Set multimeter to dc volts and connect cuitry (tele- positive meter lead to PC board A7, phone dialer). TP2 (red), and negative lead to chassis (ground). b. If meter indicates 18.5 to 21 vdc, ensure that there is a jumper between TB7-S-8, TB7, S-8 and S-9.  Set multimeter to ohms and connect leads to TB7, S-8 and TB7, S-9. c. If meter indicates 0 ohms, turn off switch S1 on power supply.  Use board ejector remove PC board A7.  Connect meter leads to J7-1 and 7. d. If meter indicates more than 100,000 ohms, inspect J12/P1, pins 19 and 34 for bro- ken or loose wires.  Resolder any bad connections on P1. e. If meter indicates 0 ohms at J4 and 7, replace PC board A7. To install new PC board, turn board so plastic ejector is toward top.  Align board with guides at top and bottom of status processor.  Slide board straight in until it contacts receptacle at back of processor.  Then press firmly on board until it seats com- pletely in receptacle. 5-18

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing