Back REPLACEMENT OF TRANSMITTER BATTERIES | Up TM-3-6665-316-12 M81 Simulator Detector Unit Chemical Agent Automatic Alarm Manual | Next REPLACEMENT OF TRANSMITTER BATTERIES (continued) |
TM 3-6665-316-12
4-11.
REPLACEMENT
OF
TRANSMITTER
BATTERIES
(continued)
a.
R e m o v al
1.
Position transmitter so that slot-head screw (1) holding cover (2) to
chassis (3) is up.
2.
Loosen screw.
3.
4.
Remove cover from chassis.
Locate battery holder (4).
Lift battery holder out of chassis until
electrical connector (5) clears rim of chassis.
Disconnect
electri-
cal connector (5) from battery holder (4).
6.
Discard batteries according to Standard Operating Procedures.
4 - 2 0
|