TM 10-8415-210-13&P 5-11.  REPLACE SNAP FASTENERS.  (CONT) c. Installing Male Section. (1) Cut a hole in the patched material (1), using a tube of the revolving punch (2).  The hole should be small enough for a tight fit around the barrel of the post (3). (2) Insert the barrel of the post (3) through the hole in the material (1) from the underside of the material. (3) Place the inserted post (3), barrel up, on the anvil (4). (4) Fit the stud (5) over the barrel of the post (3). (5) Place the cap-and-post set on the barrel of the post (3), and clinch the post (3) and stud (5) to the material (1) with a hammer blow. 5-12