TM 10-8415-208-12 2-3. EMERGENCY BREATHING APPARATUS (EBA).  (CONT) Key Fastener or Connector Function 1 Warning Light Light blinks when the remote air supply fails and the emergency air cylinder pressure drops below 1,950 PSIG.  The warning light is constantly on when the EBA is pressurized with a full cylinder to indicate the warning system is operating properly. 2 Cylinder Valve Allows air from the cylinder to be provided to the EBA if the tether line system fails. 3 Electrical Connector Connects the warning light wire to the EBA battery power source. 4 Regulator Valve Allows air pressure from the tether line or air from the cylinder into the face piece when open. 5 Pressure Gauge Indicates the amount of air remaining in the cylinder. 6 Battery Box Houses the battery to power the warning light. 7 Tether Line Connection Allows air from a remote source to be used with the EBA. 8 Communication Not used. Connection 2-5

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing