Page  Title: POWER SUPPLY CONNECTIONS
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure 2-9.  CD83OF Floor-standing Instrument Cabinet
Up
TM-10-6665-297-13P Bacharach Combustibles Gas Alarm System NSN 6665-00-410-4982 Manual
Next
Table 2-1.  AC Power Terminal Connections, CD800/830 Series Models

TM 10-6665-297-13&P 2-5 POWER SUPPLY CONNECTIONS. CD800/830 and CD832 Series Control Modules may utilize the following external power sources: 1.  120/240 VAC external power service line. 2.  Isolated 120/240 VAC plant power unit. 3.  12 VDC secondary (standby) power supply. 4.  Static power converter to accommodate 16 to 35 VDC secondary power supply (compatible with 24 V,32 V battery). 5.  12V lead-acid battery and charger. 2-5.1 POWER  CONNECTIONS.      External   power   connections   to   power   terminals   for   CD800/830   series models are designated in Table 2-1 and Figures 2-11 through 2-15. Power transformers are factory-wired for 120 VAC operation, as shown in Figure 2-10 diagram A.  Transformer wires may be reconnected for 240 VAC operation, if required, as shown in diagram B. NOTE: Model CD800X third wire ground (green) is connected to terminal board terminal labeled "GND:' Model CD800P third wire ground (green) is connected to AC power terminal strip, terminal "G." Figure 2-10.  Transformer Wiring for 120VAC and 240VAC External Power 2-5.2 DC   SECONDARY   (STANDBY)   POWER   SUPPLY.      Both   AC   and   DC   power   may   be   connected simultaneously, so that DC power will be automatically supplied should the main AC power input be interrupted. The standby power supply should not operate from the same generator, converter, or other device that provides the primary power supply.  DC + and - power connections to the control module or module assembly terminal board  are  marked  12  V,  and  +  and  -,  or  VDC,  +12  an  -,  depending  on  the  particular  model  to  be  installed (CD800P/CD802P: terminals TB-2, 6(+) and 7(-)). 2-5.3 STATIC POWER CONVERTER.  If 24-or-32-volt batteries (or other 16-to-35- 23-9617 7/3/79 2-13