Figure 1-16.  Multipoint Systems Configurations
Up
TM-10-6665-297-13P Bacharach Combustibles Gas Alarm System NSN 6665-00-410-4982 Manual
Next
Figure 1-17.  CD830W, CD832W Wall Mounting Cabinet and CD830, CD832F Floor Standing Cabinet Multi-point Control Module Configurations

TM 10-6665-297-13&P 1-3.2 CONTROL UNIT MODELS AND MODULAR CONFIGURATIONS   (continued) 1-3.2.3   Series 830 and 832 modular multipoint models: CD830R6, CD832R6: Up to six modules installed in 19-inch rack adapter (Figure 1-16) CD830P, CD832P: Up  to  six  modules  installed  in  customer's  19-inch  instrument  panel (Figure 1-16) CD830W4, CD832W4: Up   to   four   modules   with   vertical   front   panels,   enclosed   in   wall- mounting cabinet (Figure 1-16) CD830W8, CD832W8: Up to eight modules enclosed in wall-mounting cabinet (Figure 1-17) CD830F36, CD832F36: Up   to   36   individual   modules   assembled   in   floor-standing   vertical cabinet.  830 system monitors up to 36 points; 832 system monitors up to 72 points.  Combined systems are possible. (Figure 1-17) All  floor-standing  cabinets  contain  forced  ventilating  equipment  (Figure  1-18)  suspended  from  the bottom  instrument  rack.    An  integral  buzzer  controlled  by  a  thermal  switch  is  provided  to  sound  an alarm  if  fan  failure  or  other  circumstances  allow  temperatures  in  excess  of  110  degrees  F  within  the cabinet. 1-3.2.4   Special   Configurations :      Experience   indicates   that   the   configurations   listed   above   meet   most industrial   requirements.   Basic   modules   can   be   assembled   in   custom-designed   configurations   if standard assemblies do not satisfy special needs. 1-3.3 INDICATORS,  CONTROLS,  AND  ADJUSTERS .    Control  module  indicators,  controls,  and  adjusters are as follows: 1-3.3.1   Indicators (Figures 1-19, 1-20, 1-21): 1. Percent L. E. L. Indicating Meter: Indicates concentrations of combustible gases or vapors in air as percentage of lower explosive limit.  Located on control module front panel, all models. 2. Pilot Light : Glows to indicate power-on condition.  Located in power on/off pushbutton lens for pre- 1977 model CD830 modules, Figure 1-19, but on 1977 model is a green light-emitting diode near bottom left of front panel, Figure 5-1.  For locations on front panels of CD800, CD802, and CD832, see Figures 1-20 and 1-21 (labeled POWER or PILOT). 23-9617 7/1/76 1-26